| 20kW/30kW/40kW Integrated Charger | |||
| Input Characteristic |
Input voltage | 380 VAC ±15%; 480 VAC ±15% | |
| Input frequency | 50 / 60 Hz | ||
| Input type | 3P + N + PE | ||
| Power factor | 0.99 | ||
| THDi | <5% | ||
| Grounding type | TN-S, TN-CS | ||
| Output Characteristic | Connector options | CCS1 CCS2 GBT | |
| Output voltage | 200-1000 Vdc 300~1000V is the output voltage of constant power output. |
||
| Maximum output current | GBT: 125A CCS: 150A | ||
| Rated power | DC: 20kW/30kW/40kW | ||
| Peak efficiency | 96% | ||
| Environment | Operational altitude | <2000 m | |
| Operating temperature | -25 °C to +50 °C (Full power) | ||
| Temperature derating | Up to 50 °C: 100% output power, 50-65 °C interval, linear power limit, 65 °C or more, module shutdown protection. |
||
| Storage temperature range | -30 °C to +70 °C | ||
| Humidity | 5 %-95 % non-condensing | ||
| Components | Cable length | 5m (4.5m exposed from the charger) | |
| Screen | 7 inch touch display | ||
| RFID Reader | Support | ||
| Emergency button | Yes | ||
| Others | Communication interface | 4G / LAN Port | |
| Language | English,Russian,Chinese (Support OEM ) | ||
| Communication protocol | OCPP1.6J | ||
| Cooling method | Air cooled | ||
| Payment method | RFID / APP / Stand-alone mode (Mobile phone / Visa / Master is optional) |
||
| EMC | Class A (industrial) | ||
| Protection | Undervoltage protection, Overvoltage protection, DC Overcurrent, protection, Over-temperature protection, Surge Protection Device, Emergency Stop Protection |
||